Technical drawings provide supporting documentation for Ausgrid's Network Standards.
514013_1 (299kb) Standard Construction LV ABC Through Termination Construction, 1-74
514013_2 (313kb) Standard Construction LV ABC Through Termination Parrallel Bonded Construction, 1-74B
186336 (186kb) Standard Construction LV ABC Parallel Circuit Bonding Arrangements
206544 (237kb) Standard Construction LV ABC Intermediate Construction on 500mm Standoff Bracket for 0° to 30° Deviation Angle 1-80
206546 (240kb) Standard Construction LV ABC Intermediate Construction on 500mm Standoff Bracket for 30° – 60° Deviation Angle 1-83
206623 (454kb) Standard Construction LV Open Wire to ABC Through Termination Construction with Links, 1-89
206624 (370kb) Standard Construction LV Horizontal Pin Construction with LV ABC Tee Off Construction, 1-84
228823 (458kb) HV, LV and Communications Crossarm Details
232175 (458kb) Standard Construction LV ABC Offset Arm Construction for 0° to 30° Deviation Angle 1-81
234378 (151kb) Standard Construction LV Through Termination 1-11 (A) For Maintenance And Legacy Replacements Only
251901 (151kb) Standard Construction LV Conductor Termination Tie for Twin and Twist Conductors
251902 (151kb) Standard Construction LV Conductor Side Tie for Twin and Twist Conductors
251903 (151kb) Standard Construction LV Conductor Top Tie for Twin and Twist Conductors
513900 (208kb) Standard Construction LV Horizontal Pin Construction 1-1
513901 (203kb) Standard Construction LV Offset Arm Arrangement 1-2
513902 (228kb) Standard Construction LV Angle Construction 1-3
513903 (219kb) LV Termination Arrangement
513904 (261kb) LV Through Termination Arrangement
513905 (345kb) Standard Construction LV Corner Pole 4 way Through Construction 1-13
513906 (442kb) LV Corner Pole (Tee-off) Termination Arrangement
513940 (450kb) LV Corner Pole Termination Arrangement
513945 (287kb) LV Railway Termination Construction
513971 (323kb) LV Through Mains with Links
513981_1 (232kb) Standard Construction LV ABC Intermediate for 0° to 30° Deviation Angle, 1-70
513981_2 (232kb) Standard Construction LV ABC Intermediate Parallel Bonding Construction for 0° to 30° Deviation Angle, 1-70B
513982 (250kb) Standard Construction LV ABC Termination Construction, 1-71
513983 (403kb) Standard Construction LV Open Wire to ABC Through Termination Construction, 1-72
513995 (250kb) Standard Construction LV Insulator and Pin Arrangement
514012 (241kb) Standard Construction LV ABC Intermediate Construction for 30° – 60° Deviation Angle, 1-73
514014 (279kb) Standard Construction LV ABC Corner Pole Construction, 1-75
514015 (325kb) Standard Construction LV ABC Through Mains Corner Construction, 1-76
514016 (349kb) Standard Construction LV ABC Through Termination Construction with Tee-off , 1-77
514017 (346kb) Standard Construction LV ABC Intermediate Construction with Tee-off, 1-78
514052 (335kb) Standard Construction LV ABC Through Termination Construction with Links, 1-79
244670 (300kb) Standard Construction LV ABC Offset Twin Arm Construction For 0° to 30° Deviation Angle, 1-82
565720_1 Standard Construction LV ABC Constructed on Conductive Poles Below High Voltage Supply