Technical drawings provide supporting documentation for Ausgrid's Network Standards.
42087-1 Cable Routes - Concrete Marker Post Details
118205-1 Substations Underground Cables - Switchyard Cable Marker
166244-1 Standard Construction 33kV UGOH On Concrete Pole - 630mm2 to 1200mm2 - General Arrangement
166244-2 Standard Construction 33kV UGOH On Concrete Pole - 630mm2 to 1200mm2 - General Arrangement - Details and Material List
192881-1 Standard Construction 66kV UGOH On Concrete Pole - Single Cable Per Phase - General Arrangement
192881-2 Standard Construction 66kV UGOH On Concrete Pole - Single Cable Per Phase - Details and Material List
192881-3 Standard Construction 66kV UGOH On Concrete Pole - Single Cable Per Phase - Pole Head Types
202565-1 Standard Construction Guidelines for Installation of Metal Reinforcing in Footings - Concrete Walls and Cable Support Steelwork
221569-1 Standard Construction 66kV UGOH On Concrete Pole - 300mm2 to 800mm2 - Twin Cables Per Phase - General Arrangement
221569-2 Standard Construction 66kV UGOH On Concrete Pole - 300mm2 to 800mm2 - Twin Cables Per Phase - Details & Material List
221816-1 Standard Construction 132kV UGOH Termination Arrangement
221816-2 Standard Construction 132kV UGOH Termination Details
221816-3 Standard Construction 132kV UGOH Termination Pole Head Types
227403-1 Standard Construction 33kV UGOH For 3 Core Cable Flexible Terminations - General Arrangement
227403-2 Standard Construction 33kV UGOH For 3 Core Cable Flexible Terminations - Details and Material List
227403-3 Standard Construction 33kV UGOH For 3 Core Cable Flexible Terminations - Pole Head Types
229262-1 Standard Construction 33kV UGOH For Concrete Pole 300mm2 - 1600mm2 - Twin Cables Per Phase Screen Earthed Assembly - General Arrangement
229262-2 Standard Construction 33kV UGOH For Concrete Pole 300mm2 - 1600mm2 - Twin Cables Per Phase Screen Earthed Assembly - Details and Material List
229262-3 Standard Construction 33kV UGOH For Concrete Pole 300mm2 - 1600mm2 - Twin Cables Per Phase Screen Earthed Assembly - Pole Head Types
232985-1 Standard Construction 33kV UGOH For Concrete Pole 300mm2 - 1600mm2 - Flexible Non Self Supporting Termination - General Arrangement
232985-2 Standard Construction 33kV UGOH For Concrete Pole 300mm2 - 1600mm2 - Flexible Non Self Supporting Termination - Details and Material List
232985-3 Standard Construction 33kV UGOH For Concrete Pole 300mm2 - 1600mm2 - Flexible Non Self Supporting Termination - Pole Head Types
238370-1 Standard Construction 33kV UGOH Construction with OHEW on Timber Pole Single Point Bonded Earthing System - Optional LV and Streetlight Attachments - General Arrangement
238370-2 Standard Construction 33kV UGOH Construction with OHEW on Timber Pole Single Point Bonded Earthing System - Optional LV and Streetlight Attachments -Details and Material List